NRG Prairie Energy Center (ERCOT-29INR0158) — Project Summary

Queue ID
ERCOT-29INR0158
Capacity
1253 MW
Technology
Gas
Status
active
Location
Hill, TX
Region
ERCOT
Developer
NRG Prairie Energy Center LLC
IA Status
—

NRG Prairie Energy Center

ERCOT-29INR0158BetaActiveGasCombined-CycleERCOTLive · ERCOT

1,253 MW generation in Hill, TX · In queue since April 2026 · Proposed COD December 2030

BA: ERCOISO/RTO: ERCOTNERC: TRERC: ERCOT

1,253 MW

Capacity

0

Components

7 months

In Queue

—

IA Status

COD target: 2030

Asset Intelligence Map

One connected view of the asset's ownership, operating or development evidence, grid context, commercial relationships, history, and forward outlook.

5 live dimensions
4 decision models

Expand a branch, then select a fact to jump to its full section. Locked leaves open a contextual request.

Structured from the current asset record; empty data branches are omitted.Locked nodes are InfraSure decision models; no simulated values shown.
Interconnection

Total Duration

4y 8m

Pre-Study0%
Queue EntryApr 2, 2026

Interconnection request submitted to ISO/RTO

Interconnection Study

ERCOT uses a serial "connect and manage" approach — fastest among major ISOs.

Typical: 18–30 months (fastest major ISO)

Interconnection Agreement

Interconnection agreement not yet executed

Typical: 30–60 days (negotiation)

Commercial Operation

Proposed COD: 2030-12-31

Queue history
29INR0158 · 7 monthly ERCOT reports, Mar 2026 – Sep 2026

Projected COD moved

0 times

Dec 2030 → Dec 2030

Net change

0 months

first report to latest

Capacity

1253 MW

unchanged in the reports

Latest stage

Screening started

in ERCOT's latest report

Projected COD in each reportDue now (report date = COD)Milestone first reported
Screening study startedApr 2, 2026

Typical ERCOT request: projected COD moved 3 times, net +24 months (median of 2,595 requests whose COD moved). Projected COD is the developer's estimate as reported to ERCOT. Each date links to the ERCOT report it first appeared in. Source: ERCOT Generation Interconnection Status report (GIS, report type 15933).

Cross-source intelligence

Saved research · Beta
Researched Oct 25, 2026

Experimental assessment saved at the research date. See the queue record for reported project facts.

Research COD
Dec 31, 2030
From queue filing
Developer in saved assessment
NRG Energy
Filed as NRG Prairie Energy Center LLC
Status at research time
Active
Active in the ERCOT queue with no IA. The project is pre-construction: TCEQ issued a preliminary decision to approve the air permit in Oct 2026, amid local opposition and Gov. Abbott's Sept 21 directive to pause data center permits.
Financing
Not recorded
Research sources and reasoning (6 recorded sources)

medium confidence at research time

  1. einpresswire.com/article/947965376/tceq-issues-preliminary-decision-on-nrg-air-permit-for-maypearl-area-1-2-gw-data-center-power-plant
  2. datacenters.cutrerlabs.com/intel/2026-10-nrg-prairie-energy-center-tceq-preliminary-decision/
  3. interconnection.fyi/project/ercot-29inr0158
  4. cleanview.co/power-projects/planned/natural-gas-power-plants/texas/29INR0158/nrg-prairie-energy-center-
  5. ercotqueue.com/project/29INR0158
  6. gem.wiki/Prairie_Energy_Center

Commercial operation date: Only the ERCOT/LBNL filing gives a date (proposed COD 2030-12-31). The aggregators (Cleanview 'Expected online 2030', interconnection.fyi) repeat that filing and are not independent. No developer press release or financing-backed target was found.

Developer: The queue filer is the project LLC 'NRG Prairie Energy Center LLC'. Coverage of the TCEQ air permit refers to it as 'NRG's 1.2 GW Prairie Energy Center', which points to NRG as the operating parent. No ownership change was found.

Status: The LBNL status 'active' is consistent with the no-IA, pre-construction picture in the Global Energy Monitor, ercotqueue.com and permit coverage. The interxdata 'operational' label contradicts LBNL (is_operational=false) and every other source, so I disregarded it.

About

Saved background

Generated Oct 25, 2026

Figures and claims below reflect the saved summary. See the queue record for reported project facts.

The NRG Prairie Energy Center is a proposed natural gas-fired combined-cycle generation project located in Hill County, Texas. Developed by NRG Prairie Energy Center LLC, the project has a total proposed capacity of 1,253 MW. It is planned to interconnect to the transmission system at a tap on the 345 kV line between the #1907 Venus Switch and the #3389 Fort Smith Switch.

The development project is listed in the interconnection queue of the Electric Reliability Council of Texas (ERCOT) under queue ID ERCOT-29INR0158. It entered the queue on April 2, 2026, and its status is currently active. The project's proposed commercial operation date is December 31, 2030.

Summary provenance

Summary generated Oct 25, 2026 (UTC).

Source dates used by this summary were not recorded.

Dates in the current asset record

These may postdate the saved summary; they do not establish which inputs it used.

  • ERCOT queue source as of: Oct 1, 2026.
  • Queue history observations through: Sep 2026.
Development Risk

Realization risk before commercial operation — cluster-study clearance, IA timing, counterparty mix, and withdrawal probability vs cohort. The diligence view that determines whether this project is worth pursuing. Powered by InfraSure's development-stage modeling stack.

Available on the InfraSure platform

See the full development-risk decomposition for this project.

P(COD by stated date)
Withdrawal probability vs cohort
IA cluster risk
Project Details

State

TX

County

Hill

Grid Region

ERCOT (Texas)

Market

ISO/RTO Member

Developer

NRG Prairie Energy Center LLC

Utility

—

Entity

ERCOT

Service Type

—

Point of Interconnection

Tap #1907 Venus Switch – #3389 Fort Smith Switch 345 kV

Data Source

Live · ERCOT

Risk Analytics

Composite operating-phase risk view — what this asset's risk profile would look like once it reaches commercial operation. Climate hazards across its operating life, expected generation variability, and offtake counterparty exposure, decomposed into a single decision-grade score. Powered by InfraRisk.

Available on the InfraSure platform

See the full risk decomposition + scenarios for this project.

Climate hazards (8+)
Generation variability (P10/P50/P90)
Offtake + transmission counterparty
Generation Forecast

Forward generation outlook — what this project would produce assuming it reaches commercial operation. Probabilistic ranges (P10/P50/P90) across weather, demand, and policy scenarios, conditioned on the proposed COD. Powered by InfraSure's generation modeling stack.

Available on the InfraSure platform

See the full forecast + scenario decomposition for this project.

P50 conditioned on COD
Capacity factor vs cohort
Weather + policy scenarios
Financial Forecast

Forward revenue, DSCR projection, and financing-close risk — conditioned on commercial operation. The bankability view that determines whether the deal clears its covenants once online. Powered by InfraSure's asset cashflow stack.

Available on the InfraSure platform

See the full revenue + DSCR projection for this project.

Revenue conditioned on COD
Financing close risk
Cohort DSCR comparison
Market Context
Approximate
ISO / RTO
ERCOT
Trading Hub
HB_NORTH
Hub Confidence
LOW

This project's market context is estimated from its Point of Interconnection. Hub and node assignments are approximate and based on geographic inference from the POI substation name.

No insights available for this project.
InfraSure platform

Forward forecasts, scenario decomposition, and risk-decision tooling for this queue project.