Mission Station Energy Storage I (ERCOT-28INR0474) — Project Summary

Queue ID
ERCOT-28INR0474
Capacity
375 MW
Technology
Battery
Status
active
Location
Bexar, TX
Region
ERCOT
Developer
Mission Station LLC
IA Status
—

Mission Station Energy Storage I

ERCOT-28INR0474BetaActiveOtherBattery Energy StorageERCOTLive · ERCOT

375 MW hybrid in Bexar, TX · In queue since February 2026 · Proposed COD May 2030

BA: ERCOISO/RTO: ERCOTNERC: TRERC: ERCOT

375 MW

Capacity

0

Components

9 months

In Queue

—

IA Status

COD target: 2030

Asset Intelligence Map

One connected view of the asset's ownership, operating or development evidence, grid context, commercial relationships, history, and forward outlook.

5 live dimensions
4 decision models

Expand a branch, then select a fact to jump to its full section. Locked leaves open a contextual request.

Structured from the current asset record; empty data branches are omitted.Locked nodes are InfraSure decision models; no simulated values shown.
Interconnection

Total Duration

4y 3m

Pre-Study0%
Queue EntryFeb 10, 2026

Interconnection request submitted to ISO/RTO

Interconnection Study

ERCOT uses a serial "connect and manage" approach — fastest among major ISOs.

Typical: 18–30 months (fastest major ISO)

Interconnection Agreement

Interconnection agreement not yet executed

Typical: 30–60 days (negotiation)

Commercial Operation

Proposed COD: 2030-05-31

Queue history
28INR0474 · 8 monthly ERCOT reports, Feb 2026 – Sep 2026

Projected COD moved

1 time

Dec 2028 → May 2030

Net change

+17 months

first report to latest

Capacity

375 MW

unchanged in the reports

Latest stage

Screening started

in ERCOT's latest report

Projected COD in each reportDue now (report date = COD)Milestone first reported
Screening study startedFeb 10, 2026

Typical ERCOT request: projected COD moved 3 times, net +24 months (median of 2,595 requests whose COD moved). Projected COD is the developer's estimate as reported to ERCOT. Each date links to the ERCOT report it first appeared in. Source: ERCOT Generation Interconnection Status report (GIS, report type 15933).

Cross-source intelligence

Saved research · Beta
Researched Oct 25, 2026

Experimental assessment saved at the research date. See the queue record for reported project facts.

Research COD
May 31, 2030
From queue filing
Developer in saved assessment
—
From queue filing
Status at research time
Active
Active in ERCOT queue (filed 2026-02-10); no IA executed and no public construction or financing signals.
Financing
Not recorded
Research sources and reasoning (2 recorded sources)

low confidence at research time

  1. cleanview.co/power-projects/planned/battery-storage-projects/texas/28INR0474/mission-station-energy-storage-i
  2. interconnection.fyi/projects/state/TX

Commercial operation date: Only the LBNL filing gives a specific date (proposed_cod 2030-05-31). The Cleanview aggregator snippet says 'Expected online 2030', which matches but is derived from the same queue data and is not an independent developer signal.

Developer: Only the LBNL shell-LLC name 'Mission Station LLC' is available. No press release or news names a parent or operating company. The search hits on 'Mission Clean Energy' (NY) are unrelated.

Status: LBNL lists the project as active, and the interconnection.fyi listing also shows 'Active'. No contradicting news was found.

About

Saved background

Generated Apr 10, 2026 · Predates Oct 1, 2026 queue source

Figures and claims below reflect the saved summary. See the queue record for reported project facts.

Mission Station Energy Storage I is a proposed 375 MW hybrid energy project located in Bexar County, Texas. Developed by Mission Station LLC, the project consists of battery energy storage and another unspecified technology. It is currently active in the ERCOT interconnection queue as entry ERCOT-28INR0474, with a queue entry date of February 10, 2026, and a proposed commercial operation date of December 31, 2028.

The point of interconnection (POI) is Tap 345kV (Bus #5400) SPRUCE – (Bus #5475) VON_ROSE Ckt 1; Tap 345kV (Bus #5400) SPRUCE – (Bus #5231) HOWARD_5 Ckt 1. The project has been mentioned in recent news coverage related to the energy industry.

Summary provenance

Summary generated Apr 10, 2026 (UTC).

Source dates used by this summary were not recorded.

Dates in the current asset record

These may postdate the saved summary; they do not establish which inputs it used.

  • ERCOT queue source as of: Oct 1, 2026.
  • Queue history observations through: Sep 2026.
Development Risk

Realization risk before commercial operation — cluster-study clearance, IA timing, counterparty mix, and withdrawal probability vs cohort. The diligence view that determines whether this project is worth pursuing. Powered by InfraSure's development-stage modeling stack.

Available on the InfraSure platform

See the full development-risk decomposition for this project.

P(COD by stated date)
Withdrawal probability vs cohort
IA cluster risk
Project Details

State

TX

County

Bexar

Grid Region

ERCOT (Texas)

Market

ISO/RTO Member

Developer

Mission Station LLC

Utility

—

Entity

ERCOT

Service Type

—

Point of Interconnection

Tap 345kV (Bus #5400) SPRUCE – (Bus #5475) VON_ROSE Ckt 1;

Data Source

Live · ERCOT

Risk Analytics

Composite operating-phase risk view — what this asset's risk profile would look like once it reaches commercial operation. Climate hazards across its operating life, expected generation variability, and offtake counterparty exposure, decomposed into a single decision-grade score. Powered by InfraRisk.

Available on the InfraSure platform

See the full risk decomposition + scenarios for this project.

Climate hazards (8+)
Generation variability (P10/P50/P90)
Offtake + transmission counterparty
Generation Forecast

Forward generation outlook — what this project would produce assuming it reaches commercial operation. Probabilistic ranges (P10/P50/P90) across weather, demand, and policy scenarios, conditioned on the proposed COD. Powered by InfraSure's generation modeling stack.

Available on the InfraSure platform

See the full forecast + scenario decomposition for this project.

P50 conditioned on COD
Capacity factor vs cohort
Weather + policy scenarios
Financial Forecast

Forward revenue, DSCR projection, and financing-close risk — conditioned on commercial operation. The bankability view that determines whether the deal clears its covenants once online. Powered by InfraSure's asset cashflow stack.

Available on the InfraSure platform

See the full revenue + DSCR projection for this project.

Revenue conditioned on COD
Financing close risk
Cohort DSCR comparison
Market Context
Approximate
ISO / RTO
ERCOT
Trading Hub
HB_SOUTH
Hub Confidence
LOW

This project's market context is estimated from its Point of Interconnection. Hub and node assignments are approximate and based on geographic inference from the POI substation name.

No insights available for this project.
InfraSure platform

Forward forecasts, scenario decomposition, and risk-decision tooling for this queue project.