Champs Elysees BESS (ERCOT-27INR0216) — Project Summary

Queue ID
ERCOT-27INR0216
Capacity
256.1 MW
Technology
Battery
Status
active
Location
Milam, TX
Region
ERCOT
Developer
Champs Elysees Renewables, LLC
IA Status
Facility Study

Champs Elysees BESS

ERCOT-27INR0216BetaActiveBatteryERCOTLBNL + Live

256.1 MW storage in Milam, TX · In queue since August 2024 · Proposed COD December 2027

BA: ERCOISO/RTO: ERCOTNERC: TRERC: ERCOT

256.1 MW

Capacity

1

Components

Battery

1y 11m

In Queue

Facility Study

IA Phase

COD target: 2027

Interconnection

Total Duration

3y 4m

Facilities Study50%
Queue EntryAug 16, 2024

Interconnection request submitted to ISO/RTO

Interconnection StudyCurrent

ERCOT uses a serial "connect and manage" approach — fastest among major ISOs.

Typical: 18–30 months (fastest major ISO)

Interconnection Agreement

Interconnection agreement not yet executed

Typical: 30–60 days (negotiation)

Commercial Operation

Proposed COD: 2027-12-15

Cross-source intelligence
Beta
Low confidence·0 sources·as of 2026-06-01
Expected COD
2027-12-15
From queue filing
Developer
Champs Elysees Renewables, LLC
From queue filing
Status
Active
Active — Facility Study stage as of August 2024 queue entry, no public construction or financing announcements
Financing
Unannounced
Key milestones
IA executedAug 2024Most recent

Entered ERCOT queue and began Facility Study phase

About

The Champs Elysees BESS project is a proposed 256.1 MW battery storage project located in Milam County, Texas. Developed by Champs Elysees Renewables, LLC, the project consists entirely of battery storage.

The project is currently active in the ERCOT interconnection queue as entry ERCOT-27INR0216, with a queue entry date of August 16, 2024. Its proposed commercial operation date is December 15, 2027, and its interconnection agreement status is currently in the Facility Study phase. The point of interconnection is Tap 345 kV 3377 Little Pond Switch - 3704 Hog Creek Switch. The project has been mentioned in recent news coverage.

Generated from interconnection queue and public data sources

Development Risk

Realization risk before commercial operation — cluster-study clearance, IA timing, counterparty mix, and withdrawal probability vs cohort. The diligence view that determines whether this project is worth pursuing. Powered by InfraSure's development-stage modeling stack.

Available on the InfraSure platform

See the full development-risk decomposition for this project.

P(COD by stated date)
Withdrawal probability vs cohort
IA cluster risk
Project Details

State

TX

County

Milam

Grid Region

ERCOT (Texas)

Market

ISO/RTO Member

Developer

Champs Elysees Renewables, LLC

Utility

Entity

ERCOT

Service Type

Point of Interconnection

Tap 345 kV 3377 Little Pond Switch - 3704 Hog Creek Switch

Data Source

LBNL + Live

Risk Analytics

Composite operating-phase risk view — what this asset's risk profile would look like once it reaches commercial operation. Climate hazards across its operating life, expected generation variability, and offtake counterparty exposure, decomposed into a single decision-grade score. Powered by InfraRisk.

Available on the InfraSure platform

See the full risk decomposition + scenarios for this project.

Climate hazards (8+)
Generation variability (P10/P50/P90)
Offtake + transmission counterparty
Generation Forecast

Forward generation outlook — what this project would produce assuming it reaches commercial operation. Probabilistic ranges (P10/P50/P90) across weather, demand, and policy scenarios, conditioned on the proposed COD. Powered by InfraSure's generation modeling stack.

Available on the InfraSure platform

See the full forecast + scenario decomposition for this project.

P50 conditioned on COD
Capacity factor vs cohort
Weather + policy scenarios
Financial Forecast

Forward revenue, DSCR projection, and financing-close risk — conditioned on commercial operation. The bankability view that determines whether the deal clears its covenants once online. Powered by InfraSure's asset cashflow stack.

Available on the InfraSure platform

See the full revenue + DSCR projection for this project.

Revenue conditioned on COD
Financing close risk
Cohort DSCR comparison
Market Context
Approximate
ISO / RTO
ERCOT
Trading Hub
HB_NORTH
Hub Confidence
LOW

This project's market context is estimated from its Point of Interconnection. Hub and node assignments are approximate and based on geographic inference from the POI substation name.

No insights available for this project.

No Ask reports yet for this entity.

Ask about Champs Elysees BESS
InfraSure platform

Forward forecasts, scenario decomposition, and risk-decision tooling for this queue project.