CPS Rio Nogales CT201 Rotor Replacement (ERCOT-25INR0665) — Project Summary

Queue ID
ERCOT-25INR0665
Capacity
3.1 MW
Technology
Gas
Status
active
Location
Guadalupe, TX
Region
ERCOT
Developer
CPS Energy
IA Status
IA Executed

CPS Rio Nogales CT201 Rotor Replacement

ERCOT-25INR0665BetaActiveGasERCOTLBNL

3.1 MW generation in Guadalupe, TX · Proposed COD December 2025

3.1 MW

Capacity

1

Components

Gas

In Queue

IA Executed

IA Phase

Signed Feb 2025

Interconnection

IA → COD

10 months

Schedule

6 months past proposed COD

Construction75%
Queue Entry

Interconnection request submitted to ISO/RTO

Interconnection Study

ERCOT uses a serial "connect and manage" approach — fastest among major ISOs.

Typical: 18–30 months (fastest major ISO)

Interconnection AgreementFeb 7, 2025

Interconnection agreement executed — binding commitment to build

Typical: 30–60 days (negotiation)

ConstructionCurrent

Project under construction

Typical: 24–48 months

Commercial Operation

Proposed COD: 2025-12-12

About

No description available for this project.

Development Risk

Realization risk from now to commercial operation — financing close, EPC and tax-equity counterparty mix, and COD probability vs the proposed date. The diligence view that determines whether the deal actually closes. Powered by InfraSure's development-stage modeling stack.

Available on the InfraSure platform

See the full development-risk decomposition for this project.

P(COD by stated date)
Financing close probability
EPC + tax-equity counterparty
Project Details

State

TX

County

Guadalupe

Grid Region

ERCOT (Texas)

Market

ISO/RTO Member

Developer

CPS Energy

Utility

Entity

ERCOT

Service Type

Point of Interconnection

5362 RIONOG 345kV

Data Source

LBNL

Risk Analytics

Composite operating-phase risk view — what this asset's risk profile will look like once it commissions. Climate hazards across its operating life, expected generation variability, and offtake counterparty exposure, decomposed into a single decision-grade score. Powered by InfraRisk.

Available on the InfraSure platform

See the full risk decomposition + scenarios for this project.

Climate hazards (8+)
Generation variability (P10/P50/P90)
Offtake + transmission counterparty
Generation Forecast

Forward generation outlook — first-year production estimate and 10-year P50 trajectory, with probabilistic ranges (P10/P50/P90) across weather, demand, and policy scenarios. Powered by InfraSure's generation modeling stack.

Available on the InfraSure platform

See the full forecast + scenario decomposition for this project.

10-year P50 forecast
First-year output estimate
Weather + policy scenarios
Financial Forecast

Forward revenue, DSCR projection, and financing-close risk — conditioned on commercial operation. First-year DSCR, 10-year cashflow, and counterparty exposure across price and policy scenarios. Powered by InfraSure's asset cashflow stack.

Available on the InfraSure platform

See the full revenue + DSCR projection for this project.

10-year revenue projection
First-year DSCR
Financing close risk
No news available for this project.

No Ask reports yet for this entity.

Ask about CPS Rio Nogales CT201 Rotor Replacement
InfraSure platform

Forward forecasts, scenario decomposition, and risk-decision tooling for this queue project.