Project BPA-G0559 — Project Summary

Queue ID
BPA-G0559
Capacity
250 MW
Technology
Wind
Status
active
Location
Benton, WA
Region
West
Developer
IA Status
Facility Study

BPA-G0559

BPA-G0559BetaActiveWindBPALBNL

250 MW generation in Benton, WA · In queue since March 2017 · Proposed COD December 2019

BA: BPATNERC: WECCRC: RCW

250 MW

Capacity

1

Components

Wind

9y 4m

In Queue

Facility Study

IA Phase

COD target: 2019

Interconnection

Total Duration

2y 9m

Schedule

80 months past proposed COD

Facilities Study50%
Queue EntryMar 1, 2017

Interconnection request submitted to ISO/RTO

Interconnection StudyCurrent

Project undergoes interconnection studies to assess grid impact.

Typical: 18–36 months

Interconnection Agreement

Interconnection agreement not yet executed

Typical: 30–60 days (negotiation)

Commercial Operation

Proposed COD: 2019-12-01

About

The proposed BPA-G0559 project is a 250 MW wind generation facility located in Benton County, Washington. The project, under review by the Bonneville Power Administration (BPA), entered the BPA interconnection queue on March 1, 2017. Its proposed commercial operation date is December 1, 2019.

The project's interconnection status is currently in the Facility Study phase. The point of interconnection is BPA's McNary-Franklin 230 kV line. The project has appeared in recent news coverage regarding renewable energy development in the Pacific Northwest.

Generated from interconnection queue and public data sources

Development Risk

Realization risk before commercial operation — cluster-study clearance, IA timing, counterparty mix, and withdrawal probability vs cohort. The diligence view that determines whether this project is worth pursuing. Powered by InfraSure's development-stage modeling stack.

Available on the InfraSure platform

See the full development-risk decomposition for this project.

P(COD by stated date)
Withdrawal probability vs cohort
IA cluster risk
Project Details

State

WA

County

Benton

Grid Region

Mountain West

Market

Developer

Utility

Entity

BPA

Service Type

NRIS/ERIS

Point of Interconnection

BPA's McNary-Franklin 230 kV

Data Source

LBNL

Risk Analytics

Composite operating-phase risk view — what this asset's risk profile would look like once it reaches commercial operation. Climate hazards across its operating life, expected generation variability, and offtake counterparty exposure, decomposed into a single decision-grade score. Powered by InfraRisk.

Available on the InfraSure platform

See the full risk decomposition + scenarios for this project.

Climate hazards (8+)
Generation variability (P10/P50/P90)
Offtake + transmission counterparty
Generation Forecast

Forward generation outlook — what this project would produce assuming it reaches commercial operation. Probabilistic ranges (P10/P50/P90) across weather, demand, and policy scenarios, conditioned on the proposed COD. Powered by InfraSure's generation modeling stack.

Available on the InfraSure platform

See the full forecast + scenario decomposition for this project.

P50 conditioned on COD
Capacity factor vs cohort
Weather + policy scenarios
Financial Forecast

Forward revenue, DSCR projection, and financing-close risk — conditioned on commercial operation. The bankability view that determines whether the deal clears its covenants once online. Powered by InfraSure's asset cashflow stack.

Available on the InfraSure platform

See the full revenue + DSCR projection for this project.

Revenue conditioned on COD
Financing close risk
Cohort DSCR comparison
Market Context
Approximate
ISO / RTO
MOUNTAIN_WEST
Trading Hub
MID-C
Hub Confidence
UNKNOWN

This project's market context is estimated from its Point of Interconnection. Hub and node assignments are approximate and based on geographic inference from the POI substation name.

No insights available for this project.

No Ask reports yet for this entity.

Ask about Project BPA-G0559
InfraSure platform

Forward forecasts, scenario decomposition, and risk-decision tooling for this queue project.