1 MW BESS out of service in Jackson, MO
1 MW
Nameplate Capacity
1
Generators
unit
Batteries
Technology
2012
Operating Since
Coordinates
39.0402, -94.5713
County
Jackson, MO
Nearby Plants
Forward-looking, asset-specific exposure analytics combining climate hazards, generation variability, and counterparty risk into a single decision-grade view. Powered by InfraRisk.
See the full risk decomposition + scenarios for this asset.
| Field | EIA | GEM | Wikidata |
|---|---|---|---|
| Operator | Evergy Metro | Evergy Metro | — |
| Owner(s) | Evergy Metro | Evergy | — |
| Status | Out of service | — | — |
The KCP&L SmartGrid Innovation Park is a 1 MW battery energy storage system (BESS) located in Jackson County, Missouri. The plant began operating in 2012 and is owned and operated by Evergy Metro, a subsidiary of Evergy. It is interconnected to the Southwest Power Pool (SPP) balancing authority within the Midwest Reliability Organization (MRO) NERC region.
The facility utilizes lithium-ion batteries (LIB) and has a total storage capacity of 1 MWh, providing a duration of 1 hour at its full 1 MW output. The plant's primary fuel is electricity (MWH), indicating it charges from the grid. In terms of battery storage capacity, the KCP&L SmartGrid Innovation Park ranks 3rd out of 3 such facilities in Missouri, and 1198th out of 1205 nationally.
Generated from EIA, GEM, and public data sources
ISO/RTO
SPP
Market
ISO/RTO Member
NERC Region
MRO — Midwest Reliability Organization
Balancing Authority
Southwest Power Pool (SWPP)
Grid Voltage
13.8 kV
Regulatory Status
RE — Regulated
Entity Type
Investor-Owned Utility
Sector
Electric Utility
Monthly net generation as reported to EIA-923 — useful for historical context. Confidence varies sharply by fuel type; the band above and the “About this data” button explain the caveats specific to this plant and how InfraSure’s in-house model handles them.
0 MWh
Net Discharge
0 MWh
Annual Net Energy
0.0%
Capacity Factor
Positive values indicate net discharge (generation exceeds station load). Negative values indicate net charging. Pure battery storage plants are typically net negative due to round-trip efficiency losses.
Forward-looking generation outlook with probabilistic ranges across weather, demand, and policy scenarios. Powered by InfraSure's generation modeling stack.
See the full forecast + scenario decomposition for this asset.
2013
$913/kW
Est. Construction Cost
Total estimated cost: $913K
Forward revenue, DSCR bands, and refinancing risk projected under price, demand, and policy scenarios. Powered by InfraSure's asset cashflow stack.
See the full revenue + DSCR projection for this asset.
Point of Interconnection
Nearest Substation
Midtown Substation · 161 kV
Substation Distance
3.633 km
Operator
Evergy
Coord Source
OSM spatial
Market Position
ISO/RTO Market
SPP
LMP Node
KCPLHUB17
Pricing Hub
SPPSOUTH_HUB
Alt. Hub / Zone
SPPNORTH_HUB
Location Type
Settlement Location
Node Source
Curated node match
No wholesale contracts disclosed in FERC EQR for this plant.
FERC EQR captures bilateral wholesale energy + capacity contracts ≥$1M/yr filed quarterly by jurisdictional sellers — covers renewable PPAs, thermal energy sales agreements, capacity contracts, and tolling agreements alike. Many plants don't appear: regulated-utility output flows to ratepayers via cost-of-service rather than bilateral contracts; small projects fall below the filing threshold; tax-equity-financed renewables route offtake to investors not utilities; merchant plants sell into ISO clearing markets without bilateral contracts. News-extracted buyer facts (below) may surface contracts disclosed only through announcements.
No insights linked yet for this plant.
Insights enrichment runs on demand — we have the pipeline, we just haven't fetched coverage for this plant yet. Request a detailed re-run and we'll add it.
Forward forecasts, scenario decomposition, and risk-decision tooling for this asset.