Search plants, projects, owners, and states
133.4 MW Solar operating in San Bernardino, CA
133.4 MW
Nameplate Capacity
1
Generators
unit
Solar Thermal without Energy Storage
Technology
2013
Operating Since
Coordinates
35.5597, -115.4702
County
San Bernardino, CA
Nearby Plants
Forward-looking, asset-specific exposure analytics combining climate hazards, generation variability, and counterparty risk into a single decision-grade view. Powered by InfraRisk.
See the full risk decomposition + scenarios for this asset.
Request a demo →Owner data does not fully agree across sources.
EIA typically reports the operating utility, while GEM resolves to the financial owner or parent corporation. Both can be correct.
| Field | EIA | GEM | Wikidata |
|---|---|---|---|
| Operator | NRG Energy Services | NRG Energy | — |
| Owner(s) | Solar Partners I LLC | BrightSource Energy Inc | — |
| Status | Operating | operating | — |
Ivanpah 2 is a 133.4 MW solar thermal power plant located in San Bernardino County, California. The plant began operating in 2013 and is owned and operated by NRG Energy Services. It utilizes solar thermal technology without energy storage, employing dual-axis solar tracking. As of the most recent data, Ivanpah 2 ranks as the 39th largest power plant in California out of 59, and 453rd nationally out of 639 plants.
The plant's primary fuel source is the sun. In its latest annual reporting period, Ivanpah 2 generated 244,319 MWh of electricity, achieving a capacity factor of 20.9%. The plant consists of a single generator. Ivanpah 2 operates within the California Independent System Operator (CAISO) balancing authority and the Western Electricity Coordinating Council (WECC) NERC region.
Generated from EIA, GEM, and public data sources
ISO/RTO
CAISO
Market
ISO/RTO Member
NERC Region
WECC — Western Electricity Coordinating Council
Balancing Authority
California Independent System Operator (CISO)
Grid Voltage
115.0 kV
Regulatory Status
NR — Non-Regulated
Entity Type
Commercial
Sector
IPP Non-CHP
13.5K MWh
Latest Month
244.3K MWh
Annual Generation
20.9%
Capacity Factor
Forward-looking generation outlook with probabilistic ranges across weather, demand, and policy scenarios. Powered by InfraSure's generation modeling stack.
See the full forecast + scenario decomposition for this asset.
Request a demo →CO₂ Intensity
226 lb/MWh
NOx
0.021 lb/MWh
SO₂
0.001 lb/MWh
CH₄
0.004 lb/MWh
N₂O
0.000 lb/MWh
Capacity Factor
15.7%
Annual Net Gen
184 GWh
CO₂eq
227 lb/MWh
Subregion
WECC California
2013
$3,757/kW
Est. Construction Cost
Total estimated cost: $501.1M
Forward revenue, DSCR bands, and refinancing risk projected under price, demand, and policy scenarios. Powered by InfraSure's asset cashflow stack.
See the full revenue + DSCR projection for this asset.
Request a demo →Point of Interconnection
Nearest Substation
Ivanpah Substation · 230 kV
Substation Distance
0.854 km
Coord Source
OSM spatial
Market Position
ISO/RTO Market
CAISO
LMP Node
TOT210S1_7_N001
Pricing Hub
TH_ZP26_GEN-APND
Location Type
Pricing Node
Node Source
Curated node match
Last updated 2026-03-26
View all articlesNo Ask reports yet for this entity.
Ask about Ivanpah 2